Tape holding force testing machine operation guide

Tape holding force testing machine operation guide, its operation method is very simple, as long as clear the following ten steps can be, and the following Haida Xiaobian together to understand it:

1. Cut 1 inch wide strip of tape on the specified stainless steel plate;

2. Using a standard 2 kg rolling roller, roll back and forth three times at a speed of about 300 mm per minute so that the tape is uniformly distributed on the steel plate;

3. Hang the steel plate on the hook of the test box, and zero the timers and add the calibrated weight;

4. When the tape is dropped from the plate, the timer will automatically pre-store the test time;

5. The recorded test time will be used to determine the durability of tape adhesion.

Note: When hanging weights, you must confirm whether the timer is cleared!

6, according to the nameplate provides power plug AC220V 50/60HZ 10A;

7. Turn on the power switch.

8, thermostat set at 70. C, or other specified temperature.

9, all open the top two vents, in order to facilitate the smooth discharge of heat generated.

10, in addition to the temperature controller temperature settings, the other features have been locked before shipment to prohibit changes.

As long as you remember the above operation method, I believe that the operation of the tape retention tester is only a matter of time. Haida Instrument is headquartered in Dongguan and has branch offices in Chongqing, Changsha, Xiamen, Kunshan, Tianjin and Nanchang. The service to our customers, truly allow customers to buy the rest assured that with the rest assured.