1. Introduction
The RNLY / DRY-300F series intelligent thermal conductivity measuring instrument has a rotary structure. Like the RNLY / DRY-300FG series cabinet thermal conductivity instrument, the double-plate thermal protection structure is used inside. It belongs to the steady-state temperature field measurement method and conforms to the national protection plate method. Thermal conductivity measurement standard GB / T10294-2008 (Determination of steady-state thermal resistance of insulation materials and related characteristics) and international standard ISO / DIS 8302-1991, also in line with GB / T3399-1982 (Test method for thermal conductivity of plastics-heat protection flat plate method ) And GB / T10801 (polystyrene foam for thermal insulation) national standards for the measurement of thermal conductivity.
The RNLY / DRY-300F series rotary thermal conductivity instrument adopts manual clamping of the test piece, but the repeatability and accuracy of the cabinet type thermal conductivity instrument are the same. In addition, because the sample loading device uses a rotating box structure, it is not only It is suitable for flat material measurement, and also for powder / granular material measurement. In addition, by selecting the pressure or thickness online measurement module, the online measurement of the pressure and thickness of the test piece can also be automatically achieved. The RNLY / DRY-300F series cabinet thermal conductivity meter can be widely used in thermal insulation and insulation material production enterprises, national and local quality inspection departments and units, universities and research institutes and other scientific research units.
2. Main functions and features
(1) Comply with the national protection board method thermal conductivity measurement standard GB10294-2008 and international standard ISO 8302
(2) Unique double-plate structure design and insulation technology
(3) High-precision temperature detection and circuit design with temperature compensation function
(4) Fuzzy PID guard plate-hot plate temperature tracking and precise control technology
(5) Fully automatic measurement software system based on LabVIEW, powerful data analysis and output functions
(6) Unique real-time testing device for test piece pressure, real-time display, and prompt and sound alarm (optional) when exceeding the threshold
(7) Unique real-time testing device for thickness of test piece, real-time display and participation in thermal conductivity calculation (optional)
(8) Under normal environmental conditions, the instrument will not frost within the operating temperature range.
3. Technical specifications Power supply voltage: AC 220V Power: 2.0 ~ 4.0 kW
Table size: 600 × 450 × 1200mm Table weight: about 110kg
Thermal conductivity measurement:
Measuring range: 0.001 ~ 2.20 W / (m · K)
Measurement repeatability: better than ± 1.0%
Measurement accuracy: better than ± 2.5%
Temperature measurement:
Temperature range:
model
temperature range
Room temperature thermal conductivity RNLY / DRY-300F
Cold plate: room temperature + 10 ℃ ~ 100 ℃
Hot plate: room temperature + 10 ℃ ~ 100 ℃
Low temperature
Thermal conductivity
RNLY / DRY-300F-DW-5
Cold plate: 0 ℃ ~ 100 ℃
Hot plate: room temperature + 10 ℃ ~ 100 ℃
RNLY / DRY-300F-DW-15
Cold plate: -15 ℃ ~ 100 ℃
Hot plate: 0 ℃ ~ 100 ℃
RNLY / DRY-300F-DW-30
Cold plate: -30 ℃ ~ 100 ℃
Hot plate: -10 ℃ ~ 100 ℃
RNLY / DRY-300FG-DW-50
Cold plate: -50 ℃ ~ 100 ℃
Hot plate: -30 ℃ ~ 100 ℃
Medium temperature
Thermal conductivity
RNLY / DRY-300F-ZW-150
Cold plate: room temperature + 10 ℃ ~ 100 ℃
Hot plate: room temperature + 10 ℃ ~ 150 ℃
RNLY / DRY-300F-ZW-300
Cold plate: room temperature + 10 ℃ ~ 260 ℃
Hot plate: room temperature + 10 ℃ ~ 300 ℃
High temperature thermal conductivity instrument RNLY / DRY-300F-GW
Cold plate: room temperature + 10 ℃ ~ 600 ℃
Hot plate: room temperature + 10 ℃ ~ 800 ℃
Thickened thermal conductivity meter RNLY / DRY-300F-JH
Refer to the different operating temperature ranges of the above models
Tubular thermal conductivity RNLY / DRY-GX
Refer to the different operating temperature ranges of the above models
* Thermometers in other temperature ranges can be customized according to user needs.
Resolution: 0.01 ℃ Measurement accuracy: 0.1 ℃
Environmental conditions:
Room temperature: 22 ± 3 ℃ Humidity: 20 ~ 60% RH
Flat specimen requirements:
Standard size: 300mm × 300mm
thickness:
Ordinary thermal conductivity meter: 25 ± 1 mm (recommended by national standards), 5 ~ 45 mm
Thickened thermal conductivity meter: 60 ~ 100 mm
Flatness: <0.5mm
Hardness: suitable for a variety of hard and soft materials
Fourth, the instrument selection guide (relevant standards of energy-saving materials testing and instrument model comparison table)
Applicable standards
RNLY / DRY-300F
RNLY / DRY-300F-DW-5
RNLY / DRY-300F-DW-15
RNLY / DRY-300F-DW-30
GB / T11835-2007 Thermal insulation rock wool, slag wool and products
√
√
√
√
GB / T13350-2000 glass wool and its products for thermal insulation
√
√
√
√
JC / T998-2006 spray polyurethane rigid foam insulation material
√
√
√
QB / T3806-1999 Rigid polyurethane foam for building insulation
√
√
√
GB / T10801.1-2002 Molded polystyrene foam for thermal insulation
√
√
√
GB / T10801.2-2002 extruded polystyrene foam for thermal insulation
√
√
GB / T 17794-1999 flexible foam insulation products
we are mascara brush factory,all mascara brush types we can custom,such as thin mascara brush ,disposable brush ,small mascara brush ,mini mascara brush ,double mascara brush.you can use mascara brush to brush mascara eyebrow eyelash,or use for eyelash extension.we also can private label with mascara brush for you