Rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit instruction manual

Rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit Instructions for use Elisa kit Specifications: 48 well configuration / 96 well configuration standard dilution: 1.5ml × 1 bottle of enzyme standard reagent: 3 ml × 1 Bottle (48) / 6 ml × 1 bottle (96) [rat macrophage inflammatory protein 3α (MIP-3α / CCL20) ELISA kit] This reagent is only used for research use: the concentration of the standard is the abscissa , the OD value is the ordinate, the standard curve is drawn on the coordinate paper, the corresponding concentration is detected from the standard curve according to the OD value of the sample; multiplied by the dilution factor; or the standard curve is calculated by using the concentration of the standard substance and the OD value. The linear regression equation, the OD value of the sample is substituted into the equation, the sample concentration is calculated, and multiplied by the dilution factor, which is the actual concentration of the sample. Rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit consisting of: sealing film: 2 pieces (48) / 2 pieces (96) Instructions: 1 part sealed bag: 1 standard: 2700ng/L 0.5ml×1 bottle 0.5ml×1 bottle 2-8°C Preservation enzyme label coating plate: 1×48 1×96 2-8°C Preservation sample dilution: 3ml×1 bottle 6 ml×1 bottle 2- Store the developer A solution at 8 °C: 3ml × 1 bottle 6 ml × 1 bottle 2-8 ° C Preservation of the developer B solution: 3ml × 1 bottle 6 ml × 1 bottle 2-8 ° C Preservation solution: 3ml × 1 bottle 6ml × 1 bottle 2-8 ° C preservation concentrated washing solution: (20ml × 20 times) × 1 bottle (20ml × 30 times) × 1 bottle 2-8 ° C preservation of rat macrophage inflammatory protein 3α (MIP-3α / CCL20) ELISA kit Experimental principle: This kit uses the double antibody sandwich method to determine the level of rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit. The microplate was coated with purified rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit antibody to prepare solid phase antibody, and macrophage inflammatory was sequentially added to the microwell of the coated monoclonal antibody. The protein 3α (MIP-3α/CCL20) ELISA kit is combined with the HRP-labeled macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit antibody to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, add substrate TMB to develop color. TMB is converted to blue under the catalysis of HRP enzyme and converted to the final yellow color by the action of an acid. The color depth is positively correlated with the macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit in the sample. The absorbance (OD value) was measured by a microplate reader at a wavelength of 450 nm, and the concentration of the macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit in the sample was calculated by a standard curve. OBJECTIVE: This kit is used to determine the content of rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit in serum, plasma and related fluid samples. Jianglai Bio-China's old ELISA kit supplier service commitment: ? Delivery period: payment to delivery. Free technical advice and guidance during working hours? Please call to provide customers with sample testing services to maximize the effectiveness of the experimental results (free proxy). Rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit Preservation conditions and shelf life: kit storage: 2-8 ° C | Validity: 6 months [rat macrophage inflammatory protein 3α (MIP) -3α/CCL20) ELISA kit] Sample treatment and requirements: 1. Serum: room temperature blood is naturally coagulated for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if precipitation occurs during storage, it should be centrifuged again. 2. Plasma: EDTA or sodium citrate should be selected as an anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. 3. Urine: Collect with a sterile tube and centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. The chest and ascites and cerebrospinal fluid are referred to. 4. Cell culture supernatant: When detecting secreted components, collect them in a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When the components in the cells were detected, the cell suspension was diluted with PBS (pH 7.2-7.4), and the cell concentration reached about 1 million/ml. By repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again. 5. Tissue specimen: After cutting the specimen, weigh the weight. Add a certain amount of PBS, pH 7.4. It was quickly frozen and stored in liquid nitrogen for use. The specimen still maintains a temperature of 2-8 ° C after melting. A certain amount of PBS (pH 7.4) was added, and the specimen was homogenized by hand or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. One part of the package is to be tested, and the rest is frozen for use. 6. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 °C, but repeated freezing and thawing should be avoided. 7. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity. Rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit operation steps 1. Dilution and loading of standard products: 10 holes in standard wells on the enzyme label coating plate, in the first, the first Add 100 μl of the standard to the two wells, then add 50 μl of the standard dilution to the first and second wells and mix; then add 100 μl from each of the first and second wells to the third and fourth. Holes, then add 50 μl of the standard dilution solution to the third and fourth wells, and mix; then discard 50 μl in each of the third and fourth wells, and then add 50 μl to each of the fifth and sixth wells. Then, add 50 ul of the standard dilution solution in the fifth and sixth holes, and mix; after mixing, take 50 μl from each of the fifth and sixth holes and add them to the seventh and eighth holes, respectively. Add 50 μl of the standard dilution solution to the eighth well, mix and mix 50 μl from the seventh and eighth wells into the ninth and tenth holes, and add the standard dilution in the ninth and tenth holes respectively. 50 μl, after mixing, take 50 μl from each of the ninth and tenth holes and discard. (The amount of each well was 50 μl after dilution, and the concentrations were 1800 ng/L, 1200 ng/L, 600 ng/L, 300 ng/L, 150 ng/L, respectively). 2. Loading: Set blank holes separately (the blank control wells are not added with the sample and the enzyme standard reagent, the other steps are the same), and the sample holes to be tested. Add 40 μl of the sample dilution to the sample well to be tested on the enzyme-labeled plate, and then add 10 μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, and shake gently to mix. 3. Incubation: The plate was sealed with a sealing film and incubated at 37 ° C for 30 minutes. 4. Solution: 30 (48 times of 20T) concentrated washing solution was diluted with distilled water 30 (20 times of 48T) and used. 5. Washing: Carefully remove the sealing film, discard the liquid, dry it, fill each well with the washing solution, let stand for 30 seconds, then discard it, repeat 5 times, and pat dry. 6. Add enzyme: 50 μl of enzyme labeling reagent was added to each well, except for blank wells. 7. Incubation: operation is the same as 3. 8. Washing: operation is the same as 5. 9. Color: first add coloring agent A50μl to each well, then add coloring agent B50μl, gently shake and mix, avoid light at 37 °C 15 minutes. 10. Termination: 50 μl of stop solution was added to each well to terminate the reaction (when the blue color turned yellow). 11. Measurement: The absorbance (OD value) of each well was measured sequentially with a blank air conditioner of zero and a wavelength of 450 nm. The measurement should be carried out within 15 minutes after the addition of the stop solution. [rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit] Note: 1. The kit should be taken out from the refrigerated environment and allowed to equilibrate for 15-30 minutes at room temperature. If the enzyme label is unsealed after unsealing, the strip should be stored in a sealed bag. 2. Concentrated washing liquid may crystallize out. When diluted, it can be heated and dissolved in a water bath. The washing does not affect the result. 3. The sampler should be used for each step and the accuracy should be corrected frequently to avoid test errors. It is best to control the loading time within 5 minutes. If the number of specimens is large, it is recommended to use a gun. 4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is larger than the OD value of the first hole of the standard well), please first dilute the sample dilution with a certain multiple (n times) and then measure it. When calculating, multiply the total dilution by the total dilution. Multiple (×n×5). 5. The sealing film is intended for single use only to avoid cross-contamination. 6. Keep the substrate away from light. 7. Strictly follow the instructions of the manual, the test results must be based on the microplate reader reading. 8. All samples, washings and various wastes should be treated as infectious materials. 9. The different batch components of this reagent must not be mixed. 10. In the case of an English manual, the English manual shall prevail. Rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit kit performance: 1. Sample linear regression and expected concentration correlation coefficient R value of 0.95 or more. 2. Within and within the batch should be less than 9% and 11% rat macrophage inflammatory protein 3α (MIP-3α/CCL20) ELISA kit detection range: 0.2IU / L - 6IU / L

Hair Bulk And Hair Tools

Hair Bulk And Hair Tools,Bulk Human Hair,Colorful Ring,Steel Pliers

Jinan Vogue Hair Products Co., LTD , https://www.voguehairfactory.com