Activated carbon pore size distribution analyzer

Best Company has obtained 10 patents related to activated carbon pore size distribution analyzer in China,
Qualified as a high-tech enterprise in Beijing Science and Technology Park, which achieved new standards in 2009 with multiple patented technologies in China,
It is a production enterprise that has passed ISO9001 international quality system certification;
It is the creator and holder of the highest precision of dynamic chromatography specific surface analyzer;
It is the representative of the advanced and intelligent of the static volumetric adsorption instrument;
The activated carbon pore size distribution analyzer can be used for the analysis of the specific surface area of ​​battery materials, the measurement of the specific surface area of ​​catalyst materials, the determination of the total surface area and external surface area of ​​carbon black, etc.It is widely used in materials research in universities and scientific research institutes and product quality control in powder material production enterprises. The 3H-2000 series automatic nitrogen adsorption specific surface area tester developed and produced by our company is a well-known domestic brand. It entered the market in 2000. After years of continuous R & D and innovation, its performance reached the domestic leading level and the international advanced level, among which many performance indicators Beyond imported instruments, it is a model of high-precision specific surface analyzers in China. Our company has been responsible for the specific surface area testing of scientific research units such as the Institute of Physics and Chemistry, the Institute of Chemistry, Beihang University, and Beijing Institute of Technology of the Chinese Academy of Sciences for many years and has been trusted and praised. The advanced technology, stable performance and good after-sales service of the activated carbon pore size distribution analyzer instrument make our products enjoy a high reputation and trust among customers. Our company has the largest domestic customer base and is exported to Japan, Kazakhstan, Sri Lanka and other countries.

Best Instrument Technology (Beijing) Co., Ltd. is a domestic and international professional activated carbon pore size distribution analyzer, specific surface area analyzer, porosity analyzer, specific surface area tester, specific surface area analyzer manufacturer (supplier), main products There are: activated carbon pore size distribution analyzer, specific surface area analyzer, porosity analyzer, specific surface area tester, specific surface area analyzer, etc., Best Instrument Technology (Beijing) Co., Ltd. not only has the leading technical level at home and abroad, but also With good after-sales service and high-quality solutions, please call to discuss

3H-2000PS2 activated carbon pore size distribution analyzer

Advantages of activated carbon pore size distribution analyzer:

â—† It has the leading independent high-precision saturated vapor pressure (P0) real-time testing station in China;
â—† With the first domestic helium and non-helium optional test function; (with helium can improve the accuracy of the dead volume test and reduce the sample adsorption error)
â—† With domestic leading and accurate automatic liquid nitrogen surface servo intelligent retention system;
â—† With independent true density test function, helium gas test, high accuracy, independent report;
â—† It has the domestic and international leading test, automatic recovery of normal pressure after degassing, to prevent the sample from splashing;
â—† Advanced intelligent self-inspection process, intelligently determine whether the sample tube is installed, whether the test tube jacket is tightened, and whether there is air leakage;
â—† There are two modes of sample pretreatment, common mode and molecular replacement mode, which are pioneered at home and abroad;
â—† Accurate partial pressure point control mechanism, can carry out fine analysis of key aperture section according to the set requirements, and the number of analysis points can reach 1000 points;
â—† Clear and graphical graphical control interface, and all hardware control operations can be performed on the interface;
â—† It has the only intelligent control mechanism to prevent the accidental "safe drop" of the liquid nitrogen cup in China, which completely avoids the risk of the sample tube bursting due to the gas expansion of the liquid nitrogen cup accidentally falling;
â—† Super stability, even if the power is cut off unexpectedly, the current data will not be lost, and the experiment can be resumed to continue;
â—† Powerful database management function of experiment report, report query, comparison and classification management can be carried out in various ways;
â—† The automatic preview function of the data report small window, showing the results and curves at the same time;
â—† Export and import of original test data, single export and batch export of PDF reports;
â—† The whole process is automatic and intelligent operation, and the friendly human voice operation prompt;
â—† Detailed instrument operation log display and recording, all hardware actions and process progress in the automatic process of each experiment are recorded, the time is accurate to the second, which is convenient for process query and fault feedback;
â—† The instrument is equipped with a chip memory function to realize manual zero configuration of instrument hardware parameters;
â—† The detailed operation help and instruction function of the software interface, the untrained personnel can almost realize the application of the software according to the help information;
â—† Convenient automatic lid for liquid nitrogen cup;
â—† Custom style conversion of software interface;
â—† With LAN and INTERNET remote control function


Brief introduction of the performance of activated carbon pore size distribution analyzer:
Test methods: Number of analysis stations by static volume method: with 2 sample analysis stations, 1 P0 test station, and 2 sample degassing stations;
Test accuracy: High test accuracy and good reproducibility. Repeatability error is less than ± 2%;
Test range: specific surface above 0.01m2 / g, micropore 0.35-2nm; mesopore 2-50nm; macropore 50-500nm; sample types: powder, granules, fibers and sheet materials, etc. materials that can be loaded into the sample tube.
Test gas types: N2, and other adsorbed gases CO2, Ar, Kr, He, methane (CH4), benzene (C6H6), toluene (C7H8), ethanol (C2H5OH), etc .;
P0 test: It has an independent saturated vapor pressure (P0) test station to ensure high accuracy of partial pressure test;
Pressure test: original imported pressure sensor; pressure test range 0-1.6bar (0-160KPa), accuracy error ≤0.15%; micro-hole section partial pressure P / P0 can reach 1 * 10-7, the number of points is greater than 50; large holes The segment has the real-time testing function of P0, so that the control accuracy of P / P0 when approaching the spirit boundary reaches 0.998.
Sample pretreatment: Simultaneous processing of sample quantity: 2; Two-way degassing station has independent temperature control and independent timing function, which can support sample degassing processing of different temperatures and different times synchronized with the test;
Sample pretreatment mode: It has the only two optional functions of "ordinary heating and vacuum molecular diffusion mode" and "molecular replacement mode"; the molecular replacement mode has more than doubled the efficiency of the molecular diffusion mode, and can save more than half of the pretreatment Time to solve the problem of long sample preparation time in the past static method;
Test efficiency of activated carbon pore size distribution analyzer: intelligent gas flow control, small and medium adsorption samples 2-3min / partial pressure point, medium and large adsorption samples 3-5min / partial pressure point; BET multi-point method 15-30min / 1 sample ; BET single point method 6-10min / 1 sample; standard pore size test 60-120min / 1 sample; fine pore size test 120-300min / 1 sample; the above test time does not include sample pretreatment time;
Liquid nitrogen surface control: It has a liquid nitrogen surface servo holding system, which eliminates the change in the dead volume caused by the liquid nitrogen surface change caused by the liquid nitrogen volatilization during the test process, and improves the test accuracy;
Graphical control interface: Affinity control and monitoring interface, showing the complex working state of the instrument in the form of structure diagram, so that the working state of the instrument can be seen at a glance, and various valves, vacuum pumps, nitrogen cup lifts, temperature Control and wait for all hardware to operate, pleasing to the eye;
Activated carbon pore size distribution analyzer intelligent self-checking system: the instrument has hardware self-checking and air-tightness self-checking functions, which can automatically detect whether the sample tube is installed, whether the test tube jacket is tightened, and check and determine the location of the air leak, give the text Prompt and voice prompt.
Voice prompt: with unique intelligent voice prompt function;
Remote control: The instrument can be operated remotely through the local area network or the INTER network. This function is mainly convenient for after-sales and operators to remotely control and test the instrument in the laboratory in the office;


Test theory and report content of activated carbon pore size distribution analyzer:

1. Adsorption and desorption isotherms;
2. BET single-point method specific surface SBET-O
3. BET multi-point method specific surface SBET-M, BET constant CBET
4. Langmuir specific surface S Langmuir, Langmuir equilibrium constant b Langmuir
5. Statistical adsorption layer thickness method outer specific surface (STSA) S outer 6. Particle size estimation report and true density;
7. BJH method pore volume and pore size distribution; (differential, integral pore volume, pore area, pore size distribution, histogram, curve diagram)
8. MK-plate method (parallel plate model) pore volume and pore size distribution (complement to BJH method, suitable for analysis of lamellar structure materials);
9. t-plot method (Boder) micropore analysis; (Vt diagram, t method micropore pore size distribution diagram)
10. MP method (Brunauer) micropore analysis; (Vt diagram, micropore pore size distribution diagram) (this method takes into account the factors of different adsorption constants of different materials, which is closer to the true value than t-plot method)
11. DR method (Dubinin-Astakhov) micropore analysis;

Control system of activated carbon pore size distribution analyzer:

1. Powerful and stable control system; the instrument has real-time data and state saving function. Even if there are unexpected situations such as communication interruption and unexpected power failure, the instrument can still recover the test data after restarting the instrument and enter the test process to continue the test;
2. It has an intelligent and safe liquid nitrogen cup lifting control system. The key point of this system is that when an unexpected power failure occurs or the device is restarted, the operator can avoid the liquid nitrogen cup from dropping suddenly after the device is restarted. After the temperature rises, The adsorbed gas in the sample tube quickly overflows, making the sample tube burst;
3. Optimized vacuum pump start-stop management system, the vacuum pump does not need to be in the running state all the time during the test, reducing noise and extending the life of the vacuum pump;
4. Detailed instrument operation log recording function; the instrument operation log automatically records every command and execution result of the instrument during the operation of the instrument, including valve switch, pump start and stop, original data collection, etc., the time is accurate to the second. This log provides guarantee for the reliable operation and after-sales of the instrument;
Test accessories for activated carbon pore size distribution analyzer:

1. 40% pure nitrogen, purity ≥99.999%, average use time 2-3 years;
2. Beside dual-stage vacuum pump, never return oil, ultimate vacuum: 4-6 * 10-2Pa;
3. See the configuration sheet for other accessories;

Customer service of activated carbon pore size distribution analyzer.

â—† Pre-sale service
Beste provides free trial testing of samples to customers to facilitate customer comparison before purchase and understand the difference between test data and foreign instruments; in addition, we provide multiple tests to facilitate customers to evaluate the repeatability and stability of instrument testing . If you want to purchase customers need to understand the use and effect of the instrument in the use unit, our company can provide the manufacturer's telephone consultation.

â—† After-sales service
As a professional manufacturer of activated carbon pore size distribution analyzer, Best Side will provide excellent performance and reliable quality instruments, while also providing thoughtful after-sales service to completely relieve users' worries.

1. Installation, commissioning, training, transportation: free installation, commissioning, training, transportation and delivery for users.
2. Warranty period: free maintenance and other services for users during the warranty period.
3. Software upgrade: Provide users with free software upgrade service, this service is not limited by the warranty period.
4. Spare parts supply: long-term supply of spare parts and wearing parts.
5. Service methods and timeliness:
Hotline: National unified consultation telephone, the company's technical staff and sales staff will provide you with consulting services at any time.
Website: The company's website provides company introduction, product introduction, software download, data download, technical exchange, technical lectures, company news, etc.
Service: The technical staff of the company's service department will provide services at any time according to the user's request, generally no more than 48 hours from the time of receiving the request, and implement a regular or irregular return visit user system.
E-mail: The company has dedicated personnel to process and send e-mails, and will accept e-mails from you at any time and send you information such as test results, instrument information, software, etc.
Letter: There are detailed introduction materials of the company and products, we will mail them to you at any time by EMS, DHL, etc.

â—† Distributor service The sales of our company's series products are combined with direct sales and distributor channel sales. Warmly welcome interested distributors to join in cooperation in order to realize the complementarity of distributor channels and our company's product technology and achieve win-win cooperation . We will provide dealers with complete support services and excellent products.

Services for dealers mainly include:

1. Detailed introduction of all products, exquisite promotional color pages.
2. Pre-sale and after-sale technical support for a full range of products.
2. Detailed introduction and analysis of product application industries and fields, product and related knowledge training.
4. Professional in-sale support, assist the dealer in the bidding process in the bidding process, and answer the technical problems of the activated carbon pore size distribution analyzer in the bidding process.
5. To provide dealers with extremely competitive product prices to ensure the interests of dealers and end users.
6. Provide strategic framework agreements to achieve complementary advantages

Wet And Dry Cotton Soft Towel

Dry Wet Wipes,Facial Cotton Tissue,Disposable Cotton Towels,Disposable Cotton Face Towels

Shandong Tianzige International Trade Co., Ltd , https://www.chinesedipers.com