Human MEK kinase enzyme-linked immunoassay

Human MEK kinase enzyme-linked immunoassay

Kit instruction manual

Read this manual carefully before use. This ELISA kit is based on the principle of double antibody sandwich technology to detect human MEK kinase, which can only be used for research purposes, not for medical diagnosis.

Uses: Used for the determination of MEK kinase in human serum, plasma and related liquid samples.

working principle

This kit uses double antibody sandwich enzyme-linked immunosorbent assay (ELISA) to determine the level of human MEK kinase in the sample. MEK kinase was added to the enzyme-labeled wells pre-coated with human MEK kinase monoclonal antibody and incubated; after washing, HRP-labeled MEK kinase antibody was added. After incubation and washing, the unbound enzyme is removed, and then the substrates A and B are added to produce a blue color, which is converted into a final yellow color under the action of an acid. The color depth is positively correlated with the concentration of human MEK kinase in the sample.

Kit composition

1 Standard product (480pmol / L) 0.5ml 7 Developer A solution 3ml

2 Standard diluent 3ml 8 Developer B solution 3ml

3 enzyme label coating plate 12 wells × 4 strips 9 stop solution 3ml

4 enzyme labeling reagent 3ml10 instruction manual 1

520 times concentrated washing liquid 20ml11 sealing film 2 sheets

6 sample diluent 3ml12 sealed bag 1

Reagents and equipment needed but not provided

1. 37 ℃ thermostat.

2. Standard specification microplate reader.

3. Precision pipettes and disposable tips

4. Distilled water,

5. Disposable test tubes

6. Absorbent paper

Precautions

1. Remove the kit from 2-8 ° C and allow it to equilibrate at room temperature for at least 30 minutes before opening the kit. If the enzyme-coated plates are not used up after opening, the slats should be stored in sealed bags.

2. The sampler should be used at each step of sample addition, and its accuracy should be regularly checked to avoid test errors.

3. It is recommended that all standards and samples be tested in duplicate. If the content of the substance to be tested in the specimen is too high, please dilute it with the sample diluent by a certain multiple (n times) and then perform the operation according to the instructions. When calculating, please multiply the total dilution factor (× n × 5).

4. Strictly follow the instructions, and the test results must be determined by the microplate reader.

5. To avoid cross-contamination, avoid repeated use of the tip and sealing film in your hand.

6. Other unused reagents should be packed or covered. Do not mix reagents of different batches. Use before warranty.

7. Substrate B is sensitive to light and avoid prolonged exposure to light.

Washing method

Manual plate washing method: throw away the liquid in the enzyme label plate; place several layers of absorbent paper on the experimental table, and force the enzyme plate to pat several times downward; inject at least 0.35ml of the diluted washing solution into the hole and soak 2 minutes. Repeat this process several times as needed.

Automatic plate washing: If there is an automatic plate washing machine, it should be used in the formal experiment process after being used proficiently

Specimen requirements

1. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP).

2. The specimens should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided

Operating procedures

1. Dilution of standard products (this kit provides one original standard, please follow the instructions to dilute yourself in a small test tube):

240pmol / L (No. 5 standard) 120μl of the original standard, add 120μl of standard dilution

120pmol / L (No. 4 standard) 120μl No. 5 standard added 120μl standard dilution

60 pmol/L (No. 3 standard) 120μl No. 4 standard added 120μl standard dilution

30 pmol/L (No. 2 standard) 120μl No. 3 standard added 120μl standard dilution

15 pmol/L (No. 1 standard) 120μl of No. 2 standard added 120μl of standard dilution

2. Separately set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same), standard wells, and sample wells to be tested. Add 50μl of the diluted standard to the standard wells of the enzyme-coated plate; add 40μl of the sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the sample to be tested Times). Shake gently to mix, and incubate at 37 ° C for 30 minutes.

3. Discard the liquid and spin dry. Fill each well with 30-fold diluted washing liquid, shake for 30 seconds, shake off the washing liquid, and pat dry with absorbent paper. Repeat this 5 times, pat dry.

4. Add 50μl of enzyme-labeled reagent to each well, except for blank wells. Shake gently to mix, and incubate at 37 ° C for 30 minutes.

5. Discard the liquid and spin dry. Fill each well with 30-fold diluted washing liquid, shake for 30 seconds, shake off the washing liquid, and pat dry with absorbent paper. Repeat this 5 times, pat dry.

6. Add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 10 minutes.

7. Remove the enzyme labeling plate and add 50μl of stop solution to each well to stop the reaction (at this time, the blue will turn to yellow).

8. Determination: Zero the blank holes and measure the absorbance value (OD value) of each well at 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

9. Calculate the linear regression equation of the standard curve according to the concentration of the standard product and the corresponding OD value, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. It can also be calculated using various application software. It should be remembered that since the sample is diluted, its actual concentration should be multiplied by the total dilution factor.

Summary of operating procedures:

Prepare reagents, samples and standards

Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 5 times, add enzyme reagent and react at 37 ℃ for 30 minutes

Wash the plate 5 times, add color developing solutions A and B, and develop at 37 ℃ for 10 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

Detection range: 10 pmol/L→300pmol/L.

Specification: 48T / box

Storage: 2-8 ℃

Valid period: 6 months (2-8 ℃).

Shanghai Yanxin Biological Technology Co., Ltd. specializes in providing scientific research imported original and imported packaging full series of brand enzyme-linked immunoassay ELISA kits. The product range is complete, and the quality of spot supply is guaranteed for a long time. It is the designated ELISA kit supplier for many scientific research institutions and universities. Welcome new and old customers to visit us!

It is unscented and breathable. Good breathability makes you free breathing when wear it.

It is Disposable, it makes you more convenient.
It is Fashionable and very beautiful, keep you in fashion.
It is Washable, you can reuse it for several times after washing.
It is much more Softer and Skin-friendly than common PITTA mask, make you more comfortable when using it.
Higher density make it have more intensive porosity. make it more efficiently protect you from particles as dust, fog, haze, and pollen etc. It also can help to reduce transmission of flu virus, to a certain degree.
Good air permeability of it, make you easy breath when wearing it.
Mask Sponge

Mask Sponge

Mask Sponge,Safety Mask Sponge,Anti Pollution Mask Sponge,Safety Air Pollution Mask

FengRun Commodity Co.,Ltd. , https://www.sponges.nl